FUTURA air units, 2-piece., G 1/4", 0,2 to 4 bar, model series.0

Item number:

CL 014-4 FB AM

€118.93
pcs
Item description
Version:
Self-relieving filter regulator with attached lubricator

Materials:
Body: PA 66 GF60, spring hood: POM, diaphragms and seals: NBR, container: polycarbonate

Temperature range:
-10 to +50 °C

Input pressure:
1.5 - 16 bar (model series 0: 1.5 - 12 bar)

Condensate draining:
semi-automatic**

Pressure gauge connection:
G 1/4" (model series 0: G 1/8")

Pore width in the filter:
5 µm

Media:
Compressed air, neutral gases

Advantages:
•automatic venting if there is overpressure on the secondary side,
•easy assembly of single components within a model series using coupling kits,
•Handwheel can be arrested in place by pressing it down and must be locked with a lock - please use VHS 20. Model series 0 cannot be closed,
•semi-automatic oil filling by connecting a hose at the bottom to the oil bowl (G 1/8"). Through this hose, upon pressing the oil fill button, the oil is sucked into the container (not for model series 0).


Max. condensate amount:
16 cm³

Switch panel thread:
M 30x1,5

Oil metering at 1000 l/min:
approx. 10 - 20 drops/min

Oil supply:
35 cm³

Lubricator reaction limit (at 6 bar):
26 l/min

Scope of delivery:
Air unit, including pressure gauge

Flow:
26 to 800 l/min, secondary relieving: 25 l/min

Optional:
Version with metal bowl and without inspection tube -M, automatic discharge -AM, automatic discharge closed when not pressurised (0 to 12 bar) -AMNC
Properties
Ver­sion Air unit with 40 mm stan­dard manome­ter
Thread G 1/4"
Pres­sure reg­u­la­tion range [bar] 0,2 - 4
Con­tainer de­sign Plas­tic con­tainer
Con­den­sate drain au­to­matic
Pres­sure gauge dis­play [bar] 0 - 6
Mount­ing brack­ets W 0 F
Cou­pling kit KP 0 F
Cou­pling kit with wall con­sole KPW 0 F
input pres­sure [bar] 1,5 - 12
Further information on CL014-4FBAM
Weight 440 g / pcs
Customs duty number 84811005
RoHS compliant Yes
Documents
*Standard series, please prefer for use, since the pressure control range is universally usable, **As soon as the input pressure drops below the min. input pressure, the drain valve opens automatically. By screwing the drain screw tight, the semi-automatic opening of the drain valve can be prevented, *** assembly of a standard pressure gauge only possible with pressure gauge adapter, display range of the compact pressure gauge: 0 - 12 bar, or 0 - 6 bar as applicable

 
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.